Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
Dent Traumatol ; 2023 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-37818928

RESUMO

BACKGROUND/AIM: Mouthguards are used to prevent dental trauma and orofacial injuries. The aim of this study was to evaluate the influence of ethylene-vinyl acetate (EVA) aging by thermocycling on elastic modulus, stress, strain and shock absorption ability of different ethylene-vinyl acetate brands used for mouthguards. METHODS: Thirty EVA samples with a dimension of 70 × 10 × 3 mm were obtained from four commercial brands (Bioart®, Erkodent®, Polyshok® and Proform®). Fifteen samples were submitted to 10,000 cycles (5°C-55°C) in a thermocycling machine with an immersion time of 30 s and a transfer time of 5 s. The samples were submitted to a uniaxial tensile test in a universal testing machine to calculate the elastic modulus. Data were statistically evaluated by two-way ANOVA and Holm-Sidak test. A three-dimensional model of the anterior maxilla was created using Rhinoceros 5.0. A 3 mm custom-fitted mouthguard was simulated. The three-dimensional volumetric mesh was generated using the Patran software (MSC Software) with isoparametrics, 4-noded tetrahedral elements and exported to Marc/Mentat (MSC Software) as element number 134. A non-linear dynamic impact analysis was performed in which a rigid object struck the central incisor at a speed of 5 m/s. The stresses were evaluated by the modified von Mises criteria and the strains were also recorded. RESULTS: Statistically significant differences were observed for elastic modulus values (p < .001). Mean and standard deviation values (MPa) without thermocycling were: Bioart (34.5 ± 0.9), Erkodent (15.0 ± 0.4), Polyshok (17.3 ± 0.4), Proform: (20.6 ± 0.8); and with thermocycling: Bioart (25.4 ± 0.8), Erkodent (10.7 ± 0.5), Polyshok (13.3 ± 0.6), Proform (13.1 ± 0.6). The thermocycling process reduced stress and strain levels regardless of the mouthguard materials. Shock absorption ability calculated based on the strain values was increased with thermocycling process. CONCLUSION: The thermocycling process, regardless of the commercial brand, reduced the stress/strain and increased the shock absorption ability of mouthguards.

2.
Braz Oral Res ; 37: e017, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36790258

RESUMO

The aim of this study was to evaluate the effect of different die materials used in the indirect resin composite restorative technique on the fracture resistance and failure mode of restored molars and compare it with the direct resin composite restorative technique. Two flexible die silicone materials for dental models (Die Silicone - Voco and Scan die - Yller) and a type IV dental stone material (Fujirock EP - GC) were evaluated. Sixty third molars were selected and divided into four groups: indirect resin composite restoration - Die silicone (IRCR-DS); indirect resin composite restoration - Scan die (IRCR-SD); indirect resin composite restoration - Fujirock EP (IRCR-FR), and direct resin composite restoration (DRCR). Class II MOD cavities were prepared with 5 mm of buccolingual width and depth. The specimens were restored and subjected to an axial compression load until fracture, and the data were analyzed by one-way ANOVA and Tukey's HSD test (α=.05). The fracture mode was classified into restorable and unrestorable fractures. Fracture resistance values were influenced by the die material used for the IRCR fabrication and by the restorative technique (p<.001). Fracture resistance mean values and standard deviation were: IRCR-DS: 1835.5 ± 324.0 A; IRCR-SD: 1732.5 ± 384.1 AB; IRCR-FR: 1419.3 ± 318.8 BC; and DRCR: 1100.6 ± 224.9 C. Restorable fracture was more prevalent. IRCR with flexible die casts promoted higher fracture resistance and lower prevalence of unrestorable fractures.


Assuntos
Restauração Dentária Permanente , Fraturas dos Dentes , Humanos , Restauração Dentária Permanente/métodos , Preparo da Cavidade Dentária/métodos , Resinas Compostas , Dente Molar , Dente Serotino , Análise do Estresse Dentário , Teste de Materiais
3.
Dent Traumatol ; 39(3): 214-222, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36688517

RESUMO

BACKGROUND/AIM: Dentoalveolar trauma has a high incidence in different age groups, including the extremes, children, and older people. Mouth aging leads to some changes, one of them being the pulp volume reduction. The aim of this study was to evaluate the influence of different pulp cavity volumes and the impact direction on the stress and strain distribution of a maxillary central incisor. MATERIAL AND METHODS: Twenty cone beam computed tomography sets of images were selected and the pulp cavity volume was measured by ITK-SNAP software. The mean pulp cavity volume for age group of 10- to 12-year-olds was calculated to obtain the largest one. Subsequent reductions (25%, 50%, 75% and 100%) in the pulp volume values were made to simulate the aging process. The maxilla anterior segment was modeled in the Rhinoceros 5.0 software. The three-dimensional volumetric mesh was generated using the Patran software (MSC. Software), with isoparametrics, 4-noded tetrahedral elements, and exported to Marc/Mentat (MSC. Software) as element number 134. A non-linear dynamic impact analysis was performed in which a steel ball reached the central incisor at a speed of 5 m/s in the horizontal or vertical direction. The stresses were evaluated by modified von Mises stresses. The strains and the total displacement were also recorded. RESULTS: The pulp volume mean value for the age group of 10- to 12-year-olds was 65.05 mm3 . Stress concentrations were slightly different for the different pulp volumes. Impact directions resulted in different stress distribution. Higher stress values were present with the horizontal impact (range between 25.18 MPa and 24.08 MPa for enamel and 38.89 MPa and 37.03 for dentin) when compared to vertical impact (range between 15.30 MPa and 14.58 for enamel and 24.77 to 22.03 MPa for dentin). Total displacement was different for the two impact directions and higher for the horizontal impact. CONCLUSION: Pulp volume did not significantly affect the stress, strain, and total displacement during the impact but the impact direction did affect the evaluated parameters during impact.


Assuntos
Cavidade Pulpar , Polpa Dentária , Polpa Dentária/diagnóstico por imagem , Cavidade Pulpar/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico , Análise de Elementos Finitos , Estresse Mecânico
4.
Braz. oral res. (Online) ; 37: e017, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1420944

RESUMO

Abstract The aim of this study was to evaluate the effect of different die materials used in the indirect resin composite restorative technique on the fracture resistance and failure mode of restored molars and compare it with the direct resin composite restorative technique. Two flexible die silicone materials for dental models (Die Silicone - Voco and Scan die - Yller) and a type IV dental stone material (Fujirock EP - GC) were evaluated. Sixty third molars were selected and divided into four groups: indirect resin composite restoration - Die silicone (IRCR-DS); indirect resin composite restoration - Scan die (IRCR-SD); indirect resin composite restoration - Fujirock EP (IRCR-FR), and direct resin composite restoration (DRCR). Class II MOD cavities were prepared with 5 mm of buccolingual width and depth. The specimens were restored and subjected to an axial compression load until fracture, and the data were analyzed by one-way ANOVA and Tukey's HSD test (α=.05). The fracture mode was classified into restorable and unrestorable fractures. Fracture resistance values were influenced by the die material used for the IRCR fabrication and by the restorative technique (p<.001). Fracture resistance mean values and standard deviation were: IRCR-DS: 1835.5 ± 324.0 A; IRCR-SD: 1732.5 ± 384.1 AB; IRCR-FR: 1419.3 ± 318.8 BC; and DRCR: 1100.6 ± 224.9 C. Restorable fracture was more prevalent. IRCR with flexible die casts promoted higher fracture resistance and lower prevalence of unrestorable fractures.

5.
Int J Esthet Dent ; 17(3): 308-322, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36047888

RESUMO

Morphologic anterior tooth alterations and diastemata between the anterior teeth are often considered a major esthetic problem. In most cases, the treatment of these conditions involves a multidisciplinary approach. Orthodontic treatment together with direct composite resin veneers are a viable option to close diastemata and alter tooth shape. The extent and etiology of the diastemata must be considered and properly evaluated for the treatment. The present article is a case report of a patient with multiple diastemata in the maxillary anterior teeth, dental crowding, and peg-shaped lateral incisors corrected with orthodontic treatment and direct composite resin veneers. Digital planning was the tool used to decide the tooth proportions before orthodontic treatment and to guide the diagnostic wax-up. An etch-and-rinse adhesive system was applied after etching. A polychromatic layering technique under rubber dam isolation was used for the composite resin veneer construction. Finishing and polishing procedures were achieved using polishing discs and abrasive materials. Direct composite resin is an alternative that allows predictability, esthetics, and the possibility of adjustments, resulting in patient satisfaction.


Assuntos
Diastema , Dente , Resinas Compostas , Facetas Dentárias , Diastema/terapia , Estética Dentária , Humanos
6.
Dent Traumatol ; 38(5): 431-438, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35278342

RESUMO

BACKGROUND/AIM: The use of custom-fitted mouthguards can effectively prevent dentoalveolar trauma during sports practice. The aims of this study were to (1) Evaluate the elastic modulus of different EVA commercial brands used for custom-fitted mouthguards, and (2) Evaluate whether the different EVA brands can influence the stress and strain generated during an impact simulated by three-dimensional finite element analysis. METHODS: The elastic modulus of five EVA commercial brands (Essence® , Bio-Art® , Proform® , PolyShok® , and Erkodent® ) were calculated through uniaxial tensile tests. The obtained values were evaluated statistically by Kruskal-Wallis and Dunn's test. A three-dimensional model of the anterior maxilla was created using the Rhinoceros 5.0. A 3 mm custom-fitted mouthguard was simulated. The three-dimensional volumetric mesh was generated using the Patran software (MSC.Software) with isoparametrics, 4-noded tetrahedral elements, and exported to Marc/Mentat (MSC.Software) as element number 134. A non-linear dynamic impact analysis was performed in which a rigid object struck the central incisor at a speed of 5 m/s. The stresses were evaluated by the modified von Mises criteria, and the strains were also recorded. RESULTS: Statistically significant differences were observed for elastic modulus values (p < .001). Median values and the results of the Dunn's test were Essence® (38.1 A), Bio-Art® (34.9 AB), Proform® (20.8 BC), PolyShok® (17.4 CD), and Erkodent® (15.0 D) (different capital letters mean statistical differences among the groups). Stresses and strains generated in the model with mouthguards were significantly lower than the model without a mouthguard regardless of the commercial brand. There was no significant difference in the stress and strain on the enamel and dentin with the different EVA brands. The shock absorption ability was high for all the brands (more than 80%). CONCLUSION: The custom-fitted mouthguards, independently of the commercial brand, reduced stresses and strains during the impact.


Assuntos
Protetores Bucais , Desenho de Equipamento , Etilenos , Análise de Elementos Finitos , Compostos de Vinila
7.
Braz Oral Res ; 36: e009, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35081227

RESUMO

This study evaluated the optical method for measuring free total shrinkage using a Digital Single Lens Reflex (DSLR) camera. Eight composites were evaluated, conventional, bulk fill and low-shrinkage: Z100 (3M Oral Care), Gradia Direct Anterior (GC corporation), Spectra Smart (Dentsply), Filtek Z350 XT (3M Oral Care), Aura Bulk Fill (SDI), Vittra APS (FGM), Opus Bulk Fill APS (FGM), and Beautifil II LS (Shofu Inc.). The samples (6 mm diameter and 1.5 mm thick, n = 10) were placed on a polyvinylsiloxane impression material. An image of the uncured sample was captured using a DSLR camera with 105 mm macro lens and a ring flash. Samples were light cured with a 700 mW/cm2 LED light-cure unit for 40s. Post-polymerization images were captured at 2, 10 and 60 min. Projected circumferential areas of the specimens were drawn using the ImageJ software. Volumetric total shrinkage was calculated from the ratio of the areas obtained from pre- and post-curing. Results were analyzed using One-way ANOVA (α = 0.05) and Tukey test. Volumetric total shrinkage values were significantly different among the composite materials (p < .001). The volumetric shrinkage (%) mean and results of Tukey test at 60 min were: Z100: 3.45±0.30 (A); Gradia Direct Anterior: 3.00 ± 0.23 (B); Spectra Smart 2.89 ± 0.35 (B); Filtek Z350 XT: 2.65 ± 0.37 (BC); Aura Bulk Fill: 2.42 ± 0.25 (CD); Vittra APS: 2.14 ± 0.35 (DE); Opus Bulk Fill APS: 1.91 ± 0.24 (E); Beautifil II LS: 1.18 ± 0.16 (F). The optical method using a DSLR camera, was suitable for total shrinkage evaluation and will allow assessment of total shrinkage without the need for specialized equipment.


Assuntos
Resinas Compostas , Humanos , Teste de Materiais , Polimerização
8.
Braz. oral res. (Online) ; 36: e009, 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1355929

RESUMO

Abstract This study evaluated the optical method for measuring free total shrinkage using a Digital Single Lens Reflex (DSLR) camera. Eight composites were evaluated, conventional, bulk fill and low-shrinkage: Z100 (3M Oral Care), Gradia Direct Anterior (GC corporation), Spectra Smart (Dentsply), Filtek Z350 XT (3M Oral Care), Aura Bulk Fill (SDI), Vittra APS (FGM), Opus Bulk Fill APS (FGM), and Beautifil II LS (Shofu Inc.). The samples (6 mm diameter and 1.5 mm thick, n = 10) were placed on a polyvinylsiloxane impression material. An image of the uncured sample was captured using a DSLR camera with 105 mm macro lens and a ring flash. Samples were light cured with a 700 mW/cm2 LED light-cure unit for 40s. Post-polymerization images were captured at 2, 10 and 60 min. Projected circumferential areas of the specimens were drawn using the ImageJ software. Volumetric total shrinkage was calculated from the ratio of the areas obtained from pre- and post-curing. Results were analyzed using One-way ANOVA (α = 0.05) and Tukey test. Volumetric total shrinkage values were significantly different among the composite materials (p < .001). The volumetric shrinkage (%) mean and results of Tukey test at 60 min were: Z100: 3.45±0.30 (A); Gradia Direct Anterior: 3.00 ± 0.23 (B); Spectra Smart 2.89 ± 0.35 (B); Filtek Z350 XT: 2.65 ± 0.37 (BC); Aura Bulk Fill: 2.42 ± 0.25 (CD); Vittra APS: 2.14 ± 0.35 (DE); Opus Bulk Fill APS: 1.91 ± 0.24 (E); Beautifil II LS: 1.18 ± 0.16 (F). The optical method using a DSLR camera, was suitable for total shrinkage evaluation and will allow assessment of total shrinkage without the need for specialized equipment.

9.
Int J Oral Maxillofac Implants ; 36(5): 875-884, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34698712

RESUMO

PURPOSE: The aim of this systematic review was to evaluate the influence of zirconia and titanium as abutment materials on peri-implant soft tissue color. MATERIALS AND METHODS: The searched electronic databases included MEDLINE/PubMed, LILACS, Web of Science, Scopus, and LIVIVO. Two types of studies were included: randomized clinical trials (RCTs) and controlled clinical trials (CCTs) that compared zirconia (Zr) and titanium (Ti) abutments. The outcomes measured were as follows: implant crown esthetic index, visual analog scale, esthetic index, gingiva discoloration index-spectrophotometry, papilla index, recession index, and pink esthetic score. Two reviewers selected the records, assessed quality, and extracted data of included studies independently. RESULTS: A total of 323 patients enrolled in 13 studies were included in this analysis with 11 RCTs and 2 CCTs. Due to the wide variety of methodologies used, meta-analysis was only possible for RCTs that performed spectrophotometric analysis. The use of zirconia or titanium for implant abutments does not seem to be the principal factor for influencing peri-implant soft tissue color. The meta-analysis showed no difference between zirconia and titanium abutments. CONCLUSION: This study does not support any better advantage of the use of zirconia in comparison to the use of titanium related to peri-implant tissue color.


Assuntos
Dente Suporte , Titânio , Coroas , Estética Dentária , Gengiva , Humanos , Espectrofotometria , Zircônio
10.
Braz Dent J ; 31(5): 532-539, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33146338

RESUMO

The aim was to evaluate the microtensile bond strength (mTBS) to dentin and interfacial stress in a class II cavity restored with bulk-fill or conventional composite resins and the margin interfaces. Vertical slot class II cavities in the mesial face, with the gingival end in dentin, were prepared in 72 third molars, being divided into groups (n=24): G1-Tetric N-Ceram; G2-Tetric N-Ceram Bulk-Fill; G3-SonicFill. Clearfil SE Bond adhesive system was used in all groups. Half of the teeth in each group (n=12) were submitted to thermo-mechanical cycling (TMC). Restored teeth (n=9) were cut perpendicular to obtain beams, which were submitted to a mTBS test in an EMIC machine. The cervical margins in dentin of the restored teeth (n=3) were assessed using SEM through epoxy resin replicas as well as the section of the restoration. Interfacial stresses after load application were calculated by 2D finite element analysis. The mTBS means-MPa followed by different letters represent statistical difference by ANOVA and Games-Howell's test (p<0.05): Without TMC: G1-15.68±6.10a; G2-10.08±5.21ab; G3-7.98±3.76b. With TMC: G1-9.70±5.52a; G2-5.79±1.42a; G3-4.37±1.87a. Interfacial stress (MPa) was 4.4 for SonicFill, 3.9 for Tetric N-Ceram, and 3.5 for Tetric N-Ceram Bulk-Fill. SEM images showed continuous margins for all composite resin restorations. It was possible to conclude that SonicFill obtained a slightly higher interfacial stress and lower bond strength to dentin in comparison with Tetric N-Ceram and Tetric N-Ceram Bulk-Fill. Continuous margin interfaces were obtained for Tetric N-Ceram, Tetric N-Ceram Bulk-Fill, and SonicFill. However, voids were observed in the SonicFill restorations.


Assuntos
Cárie Dentária , Restauração Dentária Permanente , Resinas Compostas , Dentina , Humanos , Teste de Materiais
11.
Braz Dent J ; 31(5): 540-547, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33146339

RESUMO

The aim of this study was to analyze the influence of orthodontic bracket type (metallic or ceramic) and mouthguard on biomechanical response during impact. Two-dimensional plane-strain models of a patient with increased positive overjet of the maxillary central incisor was created based on a CT scan, simulating the periodontal ligament, bone support, gingival tissue, orthodontic brackets (metallic or ceramic) and mouthguard. A nonlinear dynamic impact finite element analysis was performed in which a steel object hit the model at 1 m/s. Stress distributions (Von Mises and Modified Von Mises) and strain were evaluated. Stress distributions were affected by the bracket presence and type. Models with metallic and ceramic bracket had higher stresses over a larger buccal enamel impact area. Models with ceramic brackets generated higher stresses than the metallic brackets. Mouthguards reduced the stress and strain values regardless of bracket type. Mouthguard shock absorption were 88.37% and 89.27% for the metallic and ceramic bracket, respectively. Orthodontic bracket presence and type influenced the stress and strain generated during an impact. Ceramic brackets generated higher stresses than metallic brackets. Mouthguards substantially reduced impact stress and strain peaks, regardless of bracket type.


Assuntos
Protetores Bucais , Braquetes Ortodônticos , Cerâmica , Análise do Estresse Dentário , Análise de Elementos Finitos , Humanos , Incisivo , Teste de Materiais , Desenho de Aparelho Ortodôntico , Estresse Mecânico
12.
J Adhes Dent ; 22(5): 503-514, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33073781

RESUMO

PURPOSE: To compare shrinkage stress, cuspal strain and fracture load of weakened premolars restored with different conventional and bulk-fill composite resins and restorative techniques. MATERIALS AND METHODS: Fifty premolars received a 4.0 x 3.5mm mesio-occlusal-distal (MOD) class II preparation. The lingual and buccal cups were internally weakened. Specimens were restored according to the following 5 groups: Filtek Z350 XT/10 increments; Filtek Z350 XT/8 increments (both 3M Oral Care); Filtek Bulk Fill Flowable Restorative + Filtek Z350 XT (both 3M Oral Care); SDR + Spectra Basic (Dentsply Sirona); and Tetric N-Ceram Bulk Fill (Ivoclar Vivadent). Cuspal strains were measured using strain gauges (n = 10). After restoration, specimens were submitted to thermal/mechanical cycles and fractured. Post-gel shrinkage of the composites was determined. Additionally, residual shrinkage strains and stresses were analyzed using three-dimensional finite element analysis (3D-FEA). The data were statistically analyzed using one-way ANOVA and Tukey's HSD (α = 0.05). RESULTS: One-way ANOVA revealed statistically significant differences among composite resins (p < 0.001) for the post-gel shrinkage. Filtek Z350 XT had the highest post-gel shrinkage and no difference was found between Spectra Basic and Tetric N-Ceram Bulk Fill (p = 0.110). The Filtek Z350 XT/10 increments, Filtek Z350 XT/8 increments and Filtek Bulk Fill Flowable Restorative/Filtek Z350 XT had statistically significantly higher cuspal deformation values when compared to the SDR/Spectra Basic and Tetric N-Ceram Bulk Fill techniques. 3D-FEA confirmed higher stress levels in the incrementally filled conventional restorations. Fracture loads were not statistically significantly different. CONCLUSION: The bulk-fill restoration techniques resulted in less cuspal strain and stress than the incremental technique with conventional composite resin. Fracture resistance was not affected by the restorative techniques.


Assuntos
Resinas Compostas , Restauração Dentária Permanente , Dente Pré-Molar , Análise do Estresse Dentário , Polimerização
13.
Braz. dent. j ; 31(5): 532-539, Sept.-Oct. 2020. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1132338

RESUMO

Abstract The aim was to evaluate the microtensile bond strength (mTBS) to dentin and interfacial stress in a class II cavity restored with bulk-fill or conventional composite resins and the margin interfaces. Vertical slot class II cavities in the mesial face, with the gingival end in dentin, were prepared in 72 third molars, being divided into groups (n=24): G1-Tetric N-Ceram; G2-Tetric N-Ceram Bulk-Fill; G3-SonicFill. Clearfil SE Bond adhesive system was used in all groups. Half of the teeth in each group (n=12) were submitted to thermo-mechanical cycling (TMC). Restored teeth (n=9) were cut perpendicular to obtain beams, which were submitted to a mTBS test in an EMIC machine. The cervical margins in dentin of the restored teeth (n=3) were assessed using SEM through epoxy resin replicas as well as the section of the restoration. Interfacial stresses after load application were calculated by 2D finite element analysis. The mTBS means-MPa followed by different letters represent statistical difference by ANOVA and Games-Howell's test (p<0.05): Without TMC: G1-15.68±6.10a; G2-10.08±5.21ab; G3-7.98±3.76b. With TMC: G1-9.70±5.52a; G2-5.79±1.42a; G3-4.37±1.87a. Interfacial stress (MPa) was 4.4 for SonicFill, 3.9 for Tetric N-Ceram, and 3.5 for Tetric N-Ceram Bulk-Fill. SEM images showed continuous margins for all composite resin restorations. It was possible to conclude that SonicFill obtained a slightly higher interfacial stress and lower bond strength to dentin in comparison with Tetric N-Ceram and Tetric N-Ceram Bulk-Fill. Continuous margin interfaces were obtained for Tetric N-Ceram, Tetric N-Ceram Bulk-Fill, and SonicFill. However, voids were observed in the SonicFill restorations.


Resumo O objetivo foi avaliar a resistência de união à microtração (RUμT) à dentina e o estresse interfacial em cavidades classe II restauradas com resina composta de incremento único ou convencional e as interfaces marginais. Cavidades classe II na face mesial, com margem gengival em dentina, foram confeccionadas em 72 terceiros molares, sendo divididos em grupos (n=24): Grupo 1-Tetric N-Ceram; Grupo 2- Tetric N-Ceram Bulk-Fill; Grupo 3- SonicFill. O Sistema adesivo Clearfil SE Bond foi usado em todos os grupos. Metade dos dentes de cada grupo (n=12) foram submetidos à ciclagem termo-mecânica (CTM). Os dentes restaurados (n=9) foram cortados perpendicularmente para obter palitos que foram submetidos ao teste de RµT na máquina-EMIC. As margens cervicais em dentina dos dentes restaurados (n=3) foram observados em microscopia eletrônica de varredura (MEV) por meio de réplicas em resina epoxy, assim como os cortes das restaurações. O estresse interfacial após a aplicação da carga foram calculadas por análise de elementos finitos 2D. As médias de RUμT-MPa seguidas de letras distintas apresentam diferença estatística de acordo com ANOVA e teste de Games-Howell (p<0,05): Antes da CTM: G1-15.68±6.10a; G2-10.08±5.21ab; G3-7.98±3.76b. Após CTM: G1-9.70±5.52a; G2-5.79±1.42a; G3-4.37±1.87a. O estresse interfacial (MPa) foi 4,4 para SonicFill, 3,9 para Tetric N-Ceram e 3,5 para Tetric N-Ceram Bulk-Fill. Imagens em MEV mostraram margens contínuas para todas as restaurações em resina composta. Foi possível concluir que o SonicFill obteve um estresse interfacial ligeiramente mais alto e menor resistência de união à dentina em comparação com o Tetric N-Ceram e o Tetric N-Ceram Bulk-Fill. Interfaces de margem contínua foram obtidas para Tetric N-Ceram, Tetric N-Ceram Bulk-Fill e SonicFill. Entretanto, espaços vazios foram observados nas restaurações do SonicFill.


Assuntos
Humanos , Cárie Dentária , Restauração Dentária Permanente , Teste de Materiais , Resinas Compostas , Dentina
14.
Dent Traumatol ; 35(4-5): 276-284, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31054190

RESUMO

BACKGROUND/AIM: Maxillary canines have a high incidence of impaction which may be associated with unexpected damage during maxillofacial trauma. The aim of this study was to evaluate how an impacted canine could influence the stress distribution in the dentoalveolar complex during a simulated impact before and after surgical removal plus the protective effect offered by a mouthguard. MATERIALS AND METHODS: Cross-sectional finite element models of the central incisor and support structures of a patient with an impacted canine in a transverse position were made using ImageJ and Marc/Mentat software. The following impact conditions were simulated: (a) incisor with impacted canine; (b) incisor with surgical socket after impacted canine extraction; and (c) incisor after bone healing. The impacts were also simulated with a 3 mm custom-fitted ethylene vinyl acetate mouthguard. A non-linear dynamic impact finite element analysis was performed in which a rigid object hit the model at 1 m/s. Maximum and minimum principal stresses as well as von Mises stresses were analyzed. RESULTS: Higher values of compressive and tensile stresses occurred on the cortical bone in the models after impacted canine extraction. The highest stress concentrations in the enamel and dentin structures were observed after bone healing. The mouthguard reduced the stress in the alveolar bone and dental structures. CONCLUSIONS: Use of mouthguards during impact reduced the compressive and tensile stresses in the alveolar bone, mainly in the fragile regions of the impacted canine or surgical socket.


Assuntos
Análise do Estresse Dentário , Protetores Bucais , Traumatismos Dentários , Dente Impactado , Fenômenos Biomecânicos , Estudos Transversais , Desenho de Equipamento , Análise de Elementos Finitos , Humanos , Maxila
15.
Dent Traumatol ; 35(2): 128-134, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30466155

RESUMO

BACKGROUND/AIMS: Dental trauma is the cause of several consequences to the injured tooth. However, the stresses and strains at adjacent teeth non-directly impacted as a possible cause of sequelae are still unknown. The aim of this study was to evaluate the stress distribution in incisors adjacent to an upper central incisor when it suffers a frontal impact in order to identify a potential explanation for sequelae in non-traumatized teeth. MATERIALS AND METHODS: A three-dimensional (3D) finite element model of the maxillary central incisors, lateral incisors and canines was created from a cone-beam scan of a patient with normal occlusion. Non-linear dynamic impact analysis was performed, simulating the right central incisor being impacted by a steel ball with a velocity of 10 m/s. A functional chewing load (100 N) on the palatal surface of the central incisor was simulated for comparison. Displacements, strains and modified von Mises stresses were calculated for the adjacent teeth. RESULTS: During impact on the central incisor, the adjacent teeth showed root displacement. Considerable stress concentrations were observed on the palatal surfaces, proximal and labial surfaces of teeth adjacent to the traumatized incisor. Stresses in the adjacent teeth were higher than stresses calculated during functional biting. Compressive stresses were concentrated at the proximal areas of the adjacent incisors. High levels of deformation were found in the root dentin of adjacent teeth during the traumatic event. CONCLUSIONS: A frontal impact on an anterior tooth generated stresses at the roots of adjacent teeth. These stresses may play a role in clinically observed sequelae of teeth adjacent to traumatized teeth.


Assuntos
Análise do Estresse Dentário , Análise de Elementos Finitos , Incisivo , Traumatismos Dentários , Humanos
16.
Braz Oral Res ; 32(suppl 1): e76, 2018 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-30365617

RESUMO

Endodontic treatment is a common dental procedure used for treating teeth which the pulp tissue has become irreversibly inflamed or necrotic as a result of the carious process or dental trauma. This procedure which involves mechanical and chemical preparation of root canal may affect several mechanical and physical properties of the tooth structure. The endodontic treatment can also influence the longevity of the rehabilitation of endodontically treated teeth and biomechanics during the oral function. For restoring endodontically treated teeth several factor and clinical decisions should be observed. The decision of the fiberglass post usage and the restorative materials are related to several factors such as the quantity and quality of remaining dental structure, presence of ferrule, post cementation length and final coronal restoration. In this review, the authors will address the effect of the endodontic treatment procedures on canal shape and mechanical properties of a tooth, and also discuss the parameters and the biomechanical principles of root canal treated teeth.


Assuntos
Restauração Dentária Permanente/métodos , Técnica para Retentor Intrarradicular , Materiais Restauradores do Canal Radicular/uso terapêutico , Tratamento do Canal Radicular/métodos , Dente não Vital/terapia , Fenômenos Biomecânicos , Análise do Estresse Dentário , Dentina/química , Dentina/patologia , Vidro , Humanos , Tratamento do Canal Radicular/instrumentação , Dente não Vital/patologia , Resultado do Tratamento
17.
Int J Oral Maxillofac Implants ; 33(2): 335-343, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29534121

RESUMO

PURPOSE: The purpose of this study was to evaluate mouthguard shock absorption ability, strain, and stress generation during impact on dental implants placed in the anterior maxilla. The mouthguard material was also characterized. MATERIALS AND METHODS: Sixty experimental models were created and divided into six groups (n = 10): implant type, external hexagon (EH) and Morse taper (MT); without and with two mouthguards (MTG), EVA custom-fitted (Ct-MTG) and standard self-adapted (St-MTG). The Shore A hardness, EVA sheet and mouthguard thickness, and elastic modulus were measured to characterize the mouthguard material. A strain gauge was attached to the palatal surface of the implant abutment, which was subjected to an impact test. Distortion of the abutment and implant was determined after impact from centroid displacements in standardized radiographic images. Two-dimensional finite element models were created to represent the six groups and were submitted to nonlinear dynamic impact analysis. The data were statistically analyzed using analysis of variance (ANOVA) and Tukey test (α = .05). RESULTS: Ct-MTG resulted in higher Shore A hardness (P < .001). After the heat-forming process, the St-MTG maintained the original thickness, but the Ct-MTG thickness had decreased. The elastic modulus of EVA was 18.1 ± 0.5 MPa. The mouthguard presence reduced strain values significantly (P < .001), particularly for Ct-MTG. There was no significant difference between implant connection types EH and MT (P = .547). CONCLUSION: The external hexagon abutment resulted in higher stress and micro-displacement values. The mouthguard was able to absorb 40% to 46% of the energy caused by the impact on the dental implant.


Assuntos
Fenômenos Biomecânicos , Projeto do Implante Dentário-Pivô , Implantes Dentários , Análise do Estresse Dentário , Análise de Elementos Finitos , Maxila/fisiopatologia , Protetores Bucais , Dente Suporte , Projeto do Implante Dentário-Pivô/métodos , Módulo de Elasticidade , Desenho de Equipamento , Dureza , Humanos , Estresse Mecânico
18.
Dent Mater ; 34(1): 152-160, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29061285

RESUMO

OBJECTIVE: The relationship between post-gel shrinkage, total shrinkage, and cuspal flexure was examined. Cuspal flexure was measured on restored typodont teeth, which offered a standardized tooth shape for comparison of shrinkage stress effects among restorative composites. METHODS: Six restorative composites were compared (Filtek LS, Venus Flowable, Tetric EvoCeram, Filtek Flowable, Esthet-X, and Filtek Supreme). Total shrinkage was determined from changes in projected surface area before and after polymerization (n=10). Post-gel shrinkage was determined with a biaxial strain gauge that measured strain development during polymerization (n=10). Cuspal flexure was determined using typodont maxillary second premolars with standard MOD slot preparation (n=10). Flexure was determined by comparing the three-dimensionally scanned cuspal surfaces before and after restoration. Restoration bonding to the typodont cavity was achieved by sandblasting and adhesive application. Bond integrity was verified by measuring dye penetration. Results were analyzed using ANOVA and Student-Newman-Keuls post hoc test (significance level 0.05). Pearson was used for correlations. RESULTS: Total and post-gel shrinkage were significant different for all composites (t-test; P<0.001). Depending on the composite, only 9-41% of the total shrinkage was recorded as post-gel shrinkage. Bond integrity of restored typodont teeth was 96-99%. Cuspal flexure correlated strongly with post-gel shrinkage, but there was no correlation with total shrinkage. SIGNIFICANCE: Cuspal flexure of restored typodont teeth showed the effect of shrinkage stress caused by polymerizing composite restorations, ensuring standardization while maintaining the effects of tooth/cavity geometry. Post-gel shrinkage gave a good indication to screen composites for the stress they may generate; total shrinkage had no direct correlation with stress.


Assuntos
Resinas Compostas/química , Restauração Dentária Permanente/métodos , Dente Pré-Molar , Adaptação Marginal Dentária , Falha de Restauração Dentária , Imageamento Tridimensional , Técnicas In Vitro , Teste de Materiais , Maleabilidade , Polimerização , Propriedades de Superfície
19.
ImplantNewsPerio ; 2(5): 895-909, set.-out. 2017. ilus
Artigo em Português | LILACS | ID: biblio-877297

RESUMO

A busca pela estética tem acentuado a procura dos pacientes pela transformação do sorriso. Com o auxílio da fotografia e da tecnologia computacional, é possível a realização do DSD (digital smile design ­ planejamento digital do sorriso), que nos dá maior previsibilidade do tratamento. A confirmação deste planejamento digital se dá na prova do mock-up, a partir do qual o paciente tem a real sensação do seu sorriso planejado. Este artigo apresentou um caso clínico no qual se destaca a adesão do paciente ao tratamento e a realização de cirurgia periodontal para aumento de coroa clínica, seguida de restaurações diretas com resinas compostas, posterior ao enceramento diagnóstico. Com o planejamento integrando a terapia cirúrgica periodontal e o protocolo restaurador adesivo direto guiado por planejamento digital (DSD), foi possível estabelecer um excelente resultado com uma elevada satisfação do paciente.


The seek for esthetics has increased patient´s demand for the smile makeover. With the help of computational technology, it is possible to perform the DSD (digital smile design) with greater treatment predictability treatment. Confirmation of this digital planning occurs in the mock-up test, from which the patient has a physical sensation of his/her planned smile. This article presents a clinical case which highlights the patient cooperation and periodontal surgery for crown lengthening, followed by direct composite resin restorations after the diagnostic wax-up procedure. With an integrated treatment planning guided by the DSD protocol, it was possible to establish an excellent outcome with high patient satisfaction.


Assuntos
Humanos , Feminino , Adulto , Resinas Compostas/uso terapêutico , Estética Dentária , Gengivoplastia/métodos , Fotografia Dentária , Sorriso , Tecnologia Odontológica
20.
J Endod ; 43(9): 1539-1544, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28735790

RESUMO

INTRODUCTION: A ferrule on anterior endodontic-treated teeth has been evaluated using clinical trials, in vitro tests, and finite element analysis (FEA). The patient-specific FEA with a nonuniform ferrule and nonlinear contact biting load associated with clinical validation can be used to predict failure. METHODS: A patient was selected with both maxillary central incisors with different ferrule designs who received endodontic treatment and restoration using a fiber post, composite core, and computer aided design and computer aided manufacturing lithium disilicate ceramic crowns. Strain gauges were attached to the buccal surfaces of both teeth to record ceramic strain during bite force recording for FEA validation. Cone-beam computed tomographic imaging was performed, and the Digital Imaging and Communication in Medicine files were exported to Mimics, 3-Matic (Materialise, Leuven, Belgium) and Patran (MSC Software, Santa Ana, CA) software to create a patient-specific FEA model. Bite load was applied using contact load applied by antagonist teeth (155 N). Mechanical properties were obtained from the literature. Modified von Mises equivalent stress was used for stress evaluation. RESULTS: Stresses on the dentin and fiber post on the left incisor, which had a nonuniform ferrule, were higher compared with the right incisor. The strain values recorded for the right central incisor (strain gauge =79.9 ± 3.8 µS and FEA = 69.5 µS) and the left central incisor (strain gauge = 83.5 ± 5.3 µS and FEA = 73.9 µS) validate the FEA analysis. CONCLUSIONS: FEA was validated with in vivo strain values measured at the buccal crown surfaces, supporting that the stress levels were realistic for investigation of the clinical performance of fiber posts. Maintaining a uniform ferrule was more favorable than a localized higher ferrule.


Assuntos
Análise de Elementos Finitos , Técnica para Retentor Intrarradicular , Dente não Vital/terapia , Humanos , Incisivo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...